The page has been translated by Gen AI.

How-to guides

Users can create the service by entering the required information for a Bare Metal Server and selecting detailed options through the Samsung Cloud Platform Console.

Create Bare Metal Server

You can create and use the Bare Metal Server service from the Samsung Cloud Platform Console.

To create a Bare Metal Server, follow these steps.

  1. All Services > Compute > Bare Metal Server Click the menu. 1. Go to the Service Home page of the Bare Metal Server.
  2. On the Service Home page, click the Create Bare Metal Server button. 2. Go to the Bare Metal Server Creation page.
  3. Bare Metal Server Creation page, enter the information required to create the service and select detailed options.
    • Select the required information in the Image and version selection area.
      Category
      required status
      Detailed description
      ImageRequiredSelect the type of Image provided
      • RHEL, Rocky Linux, Ubuntu, Windows
      • Refer to the caution information below for the server types available for each OS Image
      Image versionRequiredSelect version of the selected Image
      • Provide a version list of the provided server Image
      Table. Bare Metal Server Image and version input items
      Caution

      The server types that can be requested vary by OS image as follows.

      OS Image versions4/h4 server types3/h3 server types2/h2 server type
      Oracle Linux 9.6OOO
      RHEL 8.10XOO
      RHEL 9.4OOO
      RHEL 9.6OOO
      Rocky Linux 8.10XOO
      Rocky Linux 9.6OOO
      Ubuntu 22.04Confirmation neededOO
      Ubuntu 24.04OOConfirmation needed
      Windows 2019XOO
      Windows 2022OOO
      • s3/h3, s2/h2 server types are no longer accepting new service applications. * There is no impact on the services currently in use.
      • For Ubuntu, the server types you can request may vary depending on resource availability. * Please confirm before applying for the service.
    • Enter or select the required information in the Service Information Input area.
      Category
      required status
      Detailed description
      Number of serversRequiredNumber of Bare Metal Servers to create simultaneously
      • Only numeric input is allowed, and up to 20 servers of the same type can be created simultaneously
      Service Type > Server TypeRequiredBare Metal Server server type
      • Select the desired vCPU, Memory, and Disk specifications
      Service Type > Planned ComputeRequiredStatus of resources with Planned Compute configured
      • In Use: Number of resources with Planned Compute that are currently in use
      • Configured: Number of resources with Planned Compute configured
      • Coverage Preview: Amount applied per resource by Planned Compute
      Table. Bare Metal Server Service Information Input Items
    • In the Required Information Input area, enter or select the required information.
      Category
      required status
      Detailed description
      Administrator accountRequiredSet the administrator account and password to be used when connecting to the server
      • RHEL and Ubuntu OS are provided with a fixed root account
      • For Windows OS, enter 5 to 20 characters using lowercase letters and numbers
        • Administrator Not allowed
      Server nameRequiredWhen the selected number of servers is 1, enter a name to distinguish the Bare Metal Server
      • It must start with a lowercase English letter and be entered using lowercase letters, numbers, and special characters (-) within 3 to 15 characters
      • It must not end with a special character (-)
      • Set the hostname to the entered server name
      Server name (auto-generated number)RequiredIt is enabled when the number of selected servers is 2 or more, and you must enter a name for distinguishing the Bare Metal Server in the format name-### (e.g., test-001)
      • It must start with a lowercase English letter and be entered using lowercase letters, numbers, and special characters (-) within 3 to 15 characters
      • It must not end with a special character (-)
      • Set the hostname to the entered server name
      • Automatically generate by incrementing from the entered number by 1 (excluding numbers already in use)
      Network SettingsRequiredSet the network where the Bare Metal Server will be installed
      • Select a pre-created VPC
      • General Subnet: Select a pre-created general Subnet
        • IP can be auto-generated or user-provided, and if input is selected, the user enters the IP manually
      • NAT: Available only when there is one server and the VPC is connected to an Internet Gateway
        • When checked, a NAT IP can be selected
      • NAT IP: Select a NAT IP
        • If no NAT IP is available to select, click the Create New button to generate a Public IP
        • Click the Refresh button to view and select the generated Public IP
        • Creating a Public IP incurs charges according to the Public IP pricing policy
      • Local Subnet (optional): Choose to use a local Subnet
        • It is not a required element for creating the service
        • Select a pre-created local Subnet
        • IP can be auto-generated or user-provided, and if input is selected, the user enters the IP manually
      Table. Bare Metal Server required information entry items
Caution

Please use a firewall, etc., to control traffic access for the Bare Metal Server. Security Group is not provided.
The firewall of a Bare Metal Server can only be used to control traffic between the Bare Metal Server and Virtual Server. To use the Firewall of a Bare Metal Server, follow the steps below.

  1. Separate the VPC of Bare Metal Server: Separate them so that the Bare Metal Server and Virtual Server do not use the same VPC.
  2. Transit Gateway Creation: Create a Transit Gateway.
    • The integration between the VPC of a Virtual Server and the VPC of a Bare Metal Server uses a Transit Gateway.
    • When creating a Transit Gateway integration in the VPC of a Bare Metal Server, you must also create the Bare Metal Server’s firewall.
  3. Firewall Rule Registration: Register the rule in the Firewall of the Bare Metal Server.
  1. On the Bare Metal Server Creation page, in the Additional Information Input area, enter or select the required information.

    Category
    required status
    Detailed description
    Local disk partitionSelectionSet whether to use the local disk partition
    • Up to 10 partitions can be created, including the root partition
    • Can use up to 90% of the total capacity
    • After checking Use, you can configure partition information
    • Configure root partition information
      • Partition type: flat, lvm selectable
      • Partition name: enter partition name
        • Can be entered only when partition type is lvm
        • Enter up to 15 characters starting with a letter and containing letters, numbers, and special characters (-_)
      • Partition size: enter at least 50 GB
      • Filesystem type: select according to the used image
        • For RHEL, Rocky Linux: xfs, ext4
        • For Ubuntu: ext4, xfs, btrfs
        • For SLES: btrfs, xfs, ext4
      • Mount point: start with special character / and include letters, numbers, and special characters (-_) up to 15 characters
        • Cannot be entered when Filesystem type is swap
      • Available capacity: 90% of the default disk capacity provided when selecting a server
        • When setting partition size, the remaining capacity is automatically calculated and displayed
        • The total partition disk size cannot exceed the available capacity
    • Configure additional partition information
      • Partition type: flat, lvm selectable
      • Partition name: enter partition name
        • Partition type can be entered only when it is lvm
        • Enter up to 15 characters starting with a letter and containing letters, numbers, and special characters (-_) up to 15 characters
      • Partition size: enter at least 1 GB
      • Filesystem type: select according to the used image>
        • For RHEL, Rocky Linux: xfs, ext4, swap
        • For Ubuntu: ext4, xfs, btrfs, swap
        • For SLES: btrfs, xfs, ext4, swap
      • Mount point: start with special character / and include letters, numbers, and special characters (-_) up to 15 characters
        • Cannot be entered when Filesystem type is swap
      • Available capacity: 90% of the default disk capacity provided when selecting a server
        • When setting partition size, the remaining capacity is automatically calculated and displayed
        • The total partition disk size cannot exceed the available capacity
    Placement GroupSelectionServers belonging to the same Placement group are distributed across different racks
    • Provides distributed placement for up to two servers belonging to the same Placement group
      • For distributed placement of three or more servers, add additional Placement groups
    • Applicable only at initial creation and cannot be modified afterward
    • If you terminate the last server in a Placement group, that Placement group is automatically deleted
    LockSelectionUsing a lock prevents actions caused by mistakes, such as terminating, starting, or stopping the server.
    Init ScriptSelectionScript to run when the server starts
    • The Init Script must be selected differently depending on the Image type
      • For Windows: Select Batch Script
      • For Linux: Shell Script
    Table. Bare Metal Server Additional Information Input Items

  2. Summary Check the detailed information and estimated charges generated in the panel, and click the Create button.

    • Once creation is complete, check the created resources on the Bare Metal Server List page.

Check detailed information of Bare Metal Server

The Bare Metal Server service allows you to view and edit the complete resource list and detailed information. The Bare Metal Server Details page consists of Details, Tags, Activity History tabs.

To view detailed information about the Bare Metal Server, follow these steps.

  1. All Services > Compute > Bare Metal Server Click the menu. 1. Go to the Service Home page of the Bare Metal Server.
  2. On the Service Home page, click the Bare Metal Server menu. 2. Go to the Bare Metal Server List page.
  3. On the Bare Metal Server List page, click the resource to view detailed information. 3. Go to the Bare Metal Server Details page.
    • Bare Metal Server Details page displays status information and additional feature information, and consists of Details, Tags, Operation History tabs.
      CategoryDetailed description
      Bare Metal Server statusStatus of the Bare Metal Server created by the user
      • Creating: State while the server is being created
      • Running:: State when creation is complete and the server is usable
      • Editing:: State while the IP is being changed
      • Unknown: Error state
      • Starting: State while the server is starting
      • Stopping: State while the server is stopping
      • Stopped: State when the server has stopped
      • Terminating: State while terminating
      • Terminated: State when termination is complete
      Server operation control buttonButton to change server status
      • Start: Start a stopped server
      • Stop: Stop a running server
      Service cancellationCancel service button
      Table. Bare Metal Server status information and additional functions

Detailed Information

On the Bare Metal Server List page, you can view the detailed information of the selected resource and, if needed, modify the information.

CategoryDetailed description
serviceservice name
Resource TypeResource Type
SRNUnique resource ID in Samsung Cloud Platform
  • In Bare Metal Server, it means the Bare Metal Server SRN
Resource nameResource name
  • In Bare Metal Server, it refers to the server name
Resource IDUnique resource ID in the service
ConstructorUser who created the service
Creation date and timeService creation date and time
ModifierUser who edited the service information
Modification date and timeDate and time the service information was modified
Server nameserver name
Image/VersionServer OS image and version
Server typeDisplay vCPU and memory information
Planned ComputeResource status with Planned Compute configured
LockIndicates whether Lock is enabled/disabled
  • When Lock is enabled, it prevents server termination/start/stop actions, avoiding accidental operations
  • If you need to change the Lock property value, click the Edit button to set it
CPU settingsWhen configuring the CPU, CPU specification information and current status
  • GPU specification information: Click the Edit button to enable/disable usage and change specifications
  • GPU status: only displays Error (Error) or Editing (Editing) status
    • If in Error state, Edit is possible
Placement GroupPlacement Group name
NetworkNetwork information of the Bare Metal Server
  • VPC, standard Subnet, IP and status, Public NAT IP and status, Private NAT IP and status
  • If you need to change the IP, click the Edit button to configure
Local SubnetLocal Subnet information of the Bare Metal Server
  • Local Subnet name, Local Subnet IP, Vlan ID, Interface Name
  • If you need to add a local Subnet, click the Add button to configure
Block StorageBlock Storage information connected to the server
  • Volume name, disk type, capacity, status
  • Click the Add button to go to the Block Storage creation screen
Init ScriptView the Init Script content entered during server creation
Table. Bare Metal Server detailed information tab items

Tag

Bare Metal Server list page lets you view the tag information of the selected resource, and you can add, modify, or delete it.

CategoryDetailed description
Tag listTag list
  • You can view the Key and Value information of the tag
  • Up to 50 tags can be added per resource
  • When entering a tag, you can search and select from the list of previously created Keys and Values
Table. Bare Metal Server Tag tab items

Job History

Bare Metal Server List page allows you to view the operation history of the selected resource.

CategoryDetailed description
Task History ListResource change history
  • Operation timestamp, resource ID, resource name, operation details, event topic, operation result, check operator information
Table. Bare Metal Server Work History Tab Detailed Information Items

Bare Metal Server Resource Management

If you need server control and management functions for the created Bare Metal Server resources, you can perform tasks on the Bare Metal Server List or Bare Metal Server Details page.

Bare Metal Server Control Operation

You can start, stop, and restart a running Bare Metal Server.

Notice
  • When a Bare Metal Server is stopped, the server’s power is turned off.
  • Since stopping may affect applications or storage in use, it is recommended to shut down the OS before stopping the Bare Metal Server.
  • After shutting down the OS, be sure to also stop the console.
Caution
When starting a Bare Metal Server, be sure to start it from the Console.

To control the operation of a Bare Metal Server, follow these steps.

  1. All Services > Compute > Bare Metal Server Click the menu. 1. Go to the Service Home page of the Bare Metal Server.
  2. On the Service Home page, click the Bare Metal Server menu. 2. Go to the Bare Metal Server List page.
  3. Bare Metal Server List page, after selecting multiple servers, you can control multiple servers simultaneously using the Start and Stop buttons at the top of the table.
    • Bare Metal Server Details The page also allows you to start and stop the server.
  4. On the Bare Metal Server List page, click the resource to control its operation and navigate to the Bare Metal Server Detail page.
  5. Check the server status and click the server operation control button to complete the change.
    • Start: Start the stopped server.
    • Stop: Stops the running server.
Operation control not possible
  • If a Bare Metal Server cannot be started when a start request is made, refer to the following.
    • When Lock is enabled: Change the Lock setting to disabled, then try again.
    • If the Bare Metal Server’s status is not Stopped: Change the Bare Metal Server’s status to Stopped, then try again.
  • If a stop request for a Bare Metal Server cannot be performed, refer to the following.
    • If Lock is set: Change the Lock setting to disabled, then try again.
    • If the Bare Metal Server’s status is not Running: Change the Bare Metal Server’s status to Running, then try again.

Add Block Storage

You can add Block Storage to a Bare Metal Server.

To add Block Storage, follow the steps below.

  1. All Services > Compute > Bare Metal Server Click the menu. 1. Go to the Service Home page of the Bare Metal Server.
  2. On the Service Home page, click the Bare Metal Server menu. 2. Go to the Bare Metal Server List page.
  3. Bare Metal Server List page, click the server to which you want to add Block Storage. 3. Go to the Bare Metal Server Details page.
  4. On the Bare Metal Server Details page, click the Add button in the Block Storage section.
  5. When the popup confirming Block Storage addition opens, click the Confirm button. 5. Block Storage (BM) Creation Navigate to the page.
  6. On the Block Storage(BM) Creation page, enter the information required to create the service and create a Block Storage.
  7. Navigate to the Bare Metal Server Details page where Block Storage was added and confirm that Block Storage has been added.
Caution
After creating a Block Storage, you cannot increase its capacity.

Configure CPU

You can configure the CPU of a Bare Metal Server. To configure the CPU, follow these steps.

  1. All Services > Compute > Bare Metal Server Click the menu. 1. Go to the Service Home page of the Bare Metal Server.

  2. On the Service Home page, click the Bare Metal Server menu. 2. Go to the Bare Metal Server List page.

  3. On the Bare Metal Server List page, click the resource to configure the CPU. 3. Go to the Bare Metal Server Details page.

  4. On the Bare Metal Server Details page, click the Edit button in the CPU Settings item. 4. Edit CPU Settings A popup window opens.

  5. After entering whether to use the CPU settings and the configuration information, click the Confirm button.

    Category
    required status
    Detailed description
    Use statusRequiredSelect whether to enable the CPU setting
    • When Use is set, Thread per core and core count are required inputs
    Threads per coreRequiredSet Hyper threading usage
    • To disable Hyper threading, set Thread per core to 1
    Number of coresRequiredSet the number of vCPUs to activate
    • Changing the number of cores does not affect the price.
    Total vCPU count-The final number of vCPUs to be activated on the server
    • Automatically calculate and display the value obtained by multiplying Thread per core by number of cores
    Table. CPU configuration information items

  6. When the pop-up notifying CPU setting changes opens, click the Confirm button.

  7. Check that the CPU settings have been correctly modified on the Bare Metal Server Details page.

Caution
  • If you modify the CPU settings, they are reflected in the Console immediately, but they take effect on the actual server only after a reboot.
    • After modifying the settings, be sure to reboot (stop/start in the console) the server directly.
    • If you modify the CPU settings again before rebooting, an error occurs.
  • The number of configurable cores may vary depending on the server environment.
    • By default, it provides the option to select 25%, 50%, or 75% of the total cores.
    • Since the number of cores that can be configured when requesting a server may vary depending on the server environment, if you need any additional settings, be sure to inquire before applying for a Bare Metal Server and then proceed with the application.

Terminate Bare Metal Server

If you terminate an unused Bare Metal Server, you can reduce operating costs. However, if you terminate a Bare Metal Server, the running service may be stopped immediately, so you should proceed with the termination only after fully considering the impact of service interruption.

Caution
Please be aware that data cannot be recovered after terminating the service.
Caution
If you terminate servers one by one that have Block Storage (BM) attached, the servers will be terminated but the attached Block Storage (BM) will not be terminated, so terminate the Block Storage (BM) directly.

To cancel a Bare Metal Server, follow the steps below.

  1. All Services > Compute > Bare Metal Server Click the menu. 1. Go to the Service Home page of the Bare Metal Server.
  2. On the Service Home page, click the Bare Metal Server menu. 2. Go to the Bare Metal Server List page.
  3. On the Bare Metal Server List page, select the resource to terminate, and click the Terminate Service button.
    • You can select multiple resources and delete them simultaneously.
    • You can also delete the resource by clicking the Cancel Service button on the Bare metal Server Details page.
  4. Once the termination is complete, check the Bare Metal Server List page to see if the resource has been terminated.

Termination constraints

If a Bare Metal Server termination request cannot be completed, a popup will provide guidance. Please refer to the case below.

Cancellation not possible
  • When Block Storage(BM) is connected (simultaneous termination of two or more servers): Please disconnect the Block Storage(BM) first.

  • If File Storage is connected: First, disconnect the File Storage.

  • If Lock is set: Change the Lock setting to disabled, then try again.

  • If there are resources connected to Backup Agent or Load Balancer: First disconnect the connections of those resources.

  • If resource management tasks for Bare Metal Server are in progress on the same account: After the Bare Metal Server resource management tasks are completed, please try again.

  • If the Bare Metal Server’s status is not Running or Stopped: Change the Bare Metal Server’s status to Running or Stopped, then try again.

  • If the selection includes a server that cannot be terminated simultaneously: Select only resources that can be terminated, then try again.

Configure local Subnet

After completing the creation of a Bare Metal Server, when adding a local Subnet on the Bare Metal Server Details page, the user must manually configure the network settings of the local Subnet.

First connection (kr-west)

If there is no local subnet connected to the Bare Metal Server and you are adding the first connection, follow the guide below.

Caution

This guide applies to kr-west(Korea West) when adding the first local Subnet connection to the server.

Linux - Setting up Subnet on Ubuntu

To add a local Subnet and configure the network on an Ubuntu operating system, follow these steps.

  1. On the Bare Metal Server Details page, check the Interface Name.

  2. Retrieve the network configuration information.

    Color mode
    [root@localhost ~]# vi /etc/netplan/50-cloud-init.yaml
    network:
    ethernets:
     ens2f1:
     match:
     macaddress: 68:05:ca:d4:09:91
     mtu: 1500
     set-name: ens2f1
     ens4f1:
     match:
     macaddress: 68:05:ca:d4:09:01
     mtu: 1500
     set-name: ens4f1
    [root@localhost ~]# vi /etc/netplan/50-cloud-init.yaml
    network:
    ethernets:
     ens2f1:
     match:
     macaddress: 68:05:ca:d4:09:91
     mtu: 1500
     set-name: ens2f1
     ens4f1:
     match:
     macaddress: 68:05:ca:d4:09:01
     mtu: 1500
     set-name: ens4f1
    Code block. View network configuration file

  3. After adding a new VLAN, set the IP for the bonding configuration.

    • Replace the example code’s ID and IP with the assigned ID and IP.
      Color mode
      [root@localhost ~]# vi /etc/netplan/50-cloud-init.yaml
      network:
          bonds:
              bond-mgt:
                  interfaces:
                  - ens2f1      // **Bare Metal Server Details** Enter the Interface Name displayed on the page.
                  - ens4f1      // **Bare Metal Server Details** Enter the Interface Name shown on the page.
                  mtu: 1500
                  parameters:
                      mii-monitor-interval: 100
                      mode: active-backup
                      transmit-hash-policy: layer2
          ethernets:
              ens2f1:
                  match:
                  macaddress: 68:05:ca:d4:09:91
                  mtu: 1500
                  set-name: ens2f1
              ens4f1:
                  match:
                  macaddress: 68:05:ca:d4:09:01
                  mtu: 1500
                  set-name: ens4f1
          vlans:
              bond-mgt.20:   // Enter the Vlan ID you verified in the SCP Console instead of 20.
              addresses:
                  - 192.168.0.10/24 // Set it to the local Subnet IP confirmed in the SCP Console.
                  id: 20    // Set to the Vlan ID verified in the SCP Console.
                  link: bond-mgt
                  mtu: 1500
      [root@localhost ~]# vi /etc/netplan/50-cloud-init.yaml
      network:
          bonds:
              bond-mgt:
                  interfaces:
                  - ens2f1      // **Bare Metal Server Details** Enter the Interface Name displayed on the page.
                  - ens4f1      // **Bare Metal Server Details** Enter the Interface Name shown on the page.
                  mtu: 1500
                  parameters:
                      mii-monitor-interval: 100
                      mode: active-backup
                      transmit-hash-policy: layer2
          ethernets:
              ens2f1:
                  match:
                  macaddress: 68:05:ca:d4:09:91
                  mtu: 1500
                  set-name: ens2f1
              ens4f1:
                  match:
                  macaddress: 68:05:ca:d4:09:01
                  mtu: 1500
                  set-name: ens4f1
          vlans:
              bond-mgt.20:   // Enter the Vlan ID you verified in the SCP Console instead of 20.
              addresses:
                  - 192.168.0.10/24 // Set it to the local Subnet IP confirmed in the SCP Console.
                  id: 20    // Set to the Vlan ID verified in the SCP Console.
                  link: bond-mgt
                  mtu: 1500
      Code block. IP configuration
  4. Apply the changes to the system.

    Color mode
    # netplan apply
    # netplan apply
    Code block. Apply changes

  5. Check the interface status.

    Color mode
    # ip a
    or
    # bash /usr/local/bin/ip.sh
    # ip a
    or
    # bash /usr/local/bin/ip.sh
    Code block. Interface lookup

Linux – Configuring Subnet on CentOS/Red Hat

After adding a local Subnet on a CentOS/Red Hat operating system, follow these steps to configure the network.

Caution
Be careful, as setting the interface name incorrectly may delete the IP information currently in use.
  1. On the Bare Metal Server Details page, check the Interface Name.

  2. Modify the following command and execute it.

    Color mode
    #!/usr/bin/bash
    
    IP_ADDR="10.1.1.3/24"   // Set the local Subnet IP as observed in the Console.
    VLAN_ID="7"             // Set the Vlan ID as observed in the console.
    
    BOND_NAME="bond-mgt"
    BOND_IF_name1="ens2f1"  // Enter the Interface Name as found on the **Bare Metal Server Detailed** page.
    BOND_IF_name2="ens4f0"  // **Bare Metal Server Details** page, enter the Interface Name you verified.
    
    
    # Delete Connection
    nmcli con down "Bond ${BOND_NAME}"
    nmcli con del  "Bond ${BOND_NAME}"
    
    nmcli con down "System ${BOND_IF_name1}"
    nmcli con down "System ${BOND_IF_name2}"
    
    nmcli con del  "System ${BOND_IF_name1}"
    nmcli con del  "System ${BOND_IF_name2}"
    
    
    # Create Bonding
    nmcli con add con-name ${BOND_NAME} type bond ifname ${BOND_NAME}
    nmcli conn mod ${BOND_NAME} con-name "Bond ${BOND_NAME}"
    nmcli conn mod "Bond ${BOND_NAME}" ipv4.method    disabled
    nmcli conn mod "Bond ${BOND_NAME}" ipv6.method    ignore
    nmcli conn mod "Bond ${BOND_NAME}" connect.autoconnect yes
    
    nmcli conn mod "Bond ${BOND_NAME}" +bond.options mode=active-backup      \
                                       +bond.options xmit_hash_policy=layer2
                                       +bond.options miimon=100              \
                                       +bond.options num_grat_arp=1          \
                                       +bond.options downdelay=0
                                       +bond.options updelay=0
    
    # Assign bond-slave
    nmcli conn add type bond-slave ifname ${BOND_IF_name1}  con-name "${BOND_IF_name1}" master ${BOND_NAME}
    nmcli conn mod ${BOND_IF_name1} con-name "System ${BOND_IF_name1}"
    
    nmcli conn add type bond-slave ifname ${BOND_IF_name2}  con-name "${BOND_IF_name2}" master ${BOND_NAME}
    nmcli conn mod ${BOND_IF_name2} con-name "System ${BOND_IF_name2}"
    
    # Connection UP
    nmcli conn up   "Bond ${BOND_NAME}"
    # add vlan
    nmcli conn add type vlan ifname "${BOND_NAME}.${VLAN_ID}" con-name "${BOND_NAME}.${VLAN_ID}" id ${VLAN_ID} dev ${BOND_NAME}
    nmcli con  mod ${BOND_NAME}.${VLAN_ID} con-name "Vlan ${BOND_NAME}.${VLAN_ID}"
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv4.addresses ${IP_ADDR}
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv4.method manual
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv6.method "ignore"
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" connect.autoconnect yes
    nmcli con  up  "Vlan ${BOND_NAME}.${VLAN_ID}"
    nmcli      device reapply ${BOND_NAME}.${VLAN_ID}
    #!/usr/bin/bash
    
    IP_ADDR="10.1.1.3/24"   // Set the local Subnet IP as observed in the Console.
    VLAN_ID="7"             // Set the Vlan ID as observed in the console.
    
    BOND_NAME="bond-mgt"
    BOND_IF_name1="ens2f1"  // Enter the Interface Name as found on the **Bare Metal Server Detailed** page.
    BOND_IF_name2="ens4f0"  // **Bare Metal Server Details** page, enter the Interface Name you verified.
    
    
    # Delete Connection
    nmcli con down "Bond ${BOND_NAME}"
    nmcli con del  "Bond ${BOND_NAME}"
    
    nmcli con down "System ${BOND_IF_name1}"
    nmcli con down "System ${BOND_IF_name2}"
    
    nmcli con del  "System ${BOND_IF_name1}"
    nmcli con del  "System ${BOND_IF_name2}"
    
    
    # Create Bonding
    nmcli con add con-name ${BOND_NAME} type bond ifname ${BOND_NAME}
    nmcli conn mod ${BOND_NAME} con-name "Bond ${BOND_NAME}"
    nmcli conn mod "Bond ${BOND_NAME}" ipv4.method    disabled
    nmcli conn mod "Bond ${BOND_NAME}" ipv6.method    ignore
    nmcli conn mod "Bond ${BOND_NAME}" connect.autoconnect yes
    
    nmcli conn mod "Bond ${BOND_NAME}" +bond.options mode=active-backup      \
                                       +bond.options xmit_hash_policy=layer2
                                       +bond.options miimon=100              \
                                       +bond.options num_grat_arp=1          \
                                       +bond.options downdelay=0
                                       +bond.options updelay=0
    
    # Assign bond-slave
    nmcli conn add type bond-slave ifname ${BOND_IF_name1}  con-name "${BOND_IF_name1}" master ${BOND_NAME}
    nmcli conn mod ${BOND_IF_name1} con-name "System ${BOND_IF_name1}"
    
    nmcli conn add type bond-slave ifname ${BOND_IF_name2}  con-name "${BOND_IF_name2}" master ${BOND_NAME}
    nmcli conn mod ${BOND_IF_name2} con-name "System ${BOND_IF_name2}"
    
    # Connection UP
    nmcli conn up   "Bond ${BOND_NAME}"
    # add vlan
    nmcli conn add type vlan ifname "${BOND_NAME}.${VLAN_ID}" con-name "${BOND_NAME}.${VLAN_ID}" id ${VLAN_ID} dev ${BOND_NAME}
    nmcli con  mod ${BOND_NAME}.${VLAN_ID} con-name "Vlan ${BOND_NAME}.${VLAN_ID}"
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv4.addresses ${IP_ADDR}
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv4.method manual
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv6.method "ignore"
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" connect.autoconnect yes
    nmcli con  up  "Vlan ${BOND_NAME}.${VLAN_ID}"
    nmcli      device reapply ${BOND_NAME}.${VLAN_ID}
    Code block. IP configuration script

  3. Check the interface status.

    Color mode
    # ip a
    or
    # bash /usr/local/bin/ip.sh
    # ip a
    or
    # bash /usr/local/bin/ip.sh
    Code block. Interface lookup

Setting up Subnet in Windows

After adding a local Subnet on the Windows operating system, follow these steps to configure the network.

  1. Windows Start icon, right-click it, then run the Windows PowerShell(Administrator) program.

  2. On the Bare Metal Server Details page, check the Interface Name.

  3. Run ncpa.cpl from the Windows Run menu.

    Figure

  4. Check whether the interface is enabled, and enable it if necessary.

    • Activate the Interface Name identified on the Bare Metal Server Details page.
      Figure
  5. Create a Teaming.

    Color mode
    PS C:\> New-NetLbfoTeam Name bond-mgt TeamMembers ens2f1,ens4f1
    PS C:\> Set-NetLbfoTeam Name bond-mgt LoadBalancingAlgorithm Dynamic
    PS C:\> New-NetLbfoTeam Name bond-mgt TeamMembers ens2f1,ens4f1
    PS C:\> Set-NetLbfoTeam Name bond-mgt LoadBalancingAlgorithm Dynamic
    Code block. Create Teaming
    그림

  6. After adding a new VLAN, configure the IP.

    • Enter the VLAN ID and local Subnet IP confirmed on the Bare Metal Server Details page.
      Color mode
      PS C:\> Add-NetLbfoTeamNIC -Team bond_bond-mgt -VlanID 20 -Name bond-mgt.20
      PS C:\> Get-NetAdapter
      PS C:\> netsh interface ip set address bond-mgt.20 static 192.168.0.10/24
      PS C:\> Add-NetLbfoTeamNIC -Team bond_bond-mgt -VlanID 20 -Name bond-mgt.20
      PS C:\> Get-NetAdapter
      PS C:\> netsh interface ip set address bond-mgt.20 static 192.168.0.10/24
      Code block. Windows IP configuration
  7. In the Windows Run menu, execute ncpa.cpl to check the interface status.

First connection(kr-south)

If there is no local subnet connected to the Bare Metal Server and you are adding the first connection, follow the guide below.

Caution

This guide applies to kr-south(Korea region) when adding the first local Subnet connection to the server.

Linux - Setting up Subnet on Ubuntu

To add a local Subnet and configure the network on an Ubuntu operating system, follow these steps.

  1. After adding a new VLAN, set the IP.

    • Replace the example code’s ID and IP with the assigned ID and IP.
      Color mode
      [root@localhost ~]# vi /etc/netplan/50-cloud-init.yaml
      network:
          bonds:
              bond-mgt:
                  interfaces:
                  - ens2f1
                  - ens4f1
                  mtu: 1500
                  parameters:
                      mii-monitor-interval: 100
                      mode: active-backup
                      transmit-hash-policy: layer2
          ethernets:
              ens2f1:
                  match:
                  macaddress: 68:05:ca:d4:09:91
                  mtu: 1500
                  set-name: ens2f1
              ens4f1:
                  match:
                  macaddress: 68:05:ca:d4:09:01
                  mtu: 1500
                  set-name: ens4f1
          vlans:
              bond-mgt.20:
              addresses:
                  - 192.168.0.10/24
                  id: 20
                  link: bond-mgt
                  mtu: 1500
          vlans:
              bond-mgt.21: // Enter the VLAN ID you verified on the console instead of 21.
              addresses:
                  - 192.168.0.20/24 // Set it to the local Subnet IP verified in the console.
                  id: 21    // Set to the VLAN ID verified in the console.
                  link: bond-mgt
                  mtu: 1500
      [root@localhost ~]# vi /etc/netplan/50-cloud-init.yaml
      network:
          bonds:
              bond-mgt:
                  interfaces:
                  - ens2f1
                  - ens4f1
                  mtu: 1500
                  parameters:
                      mii-monitor-interval: 100
                      mode: active-backup
                      transmit-hash-policy: layer2
          ethernets:
              ens2f1:
                  match:
                  macaddress: 68:05:ca:d4:09:91
                  mtu: 1500
                  set-name: ens2f1
              ens4f1:
                  match:
                  macaddress: 68:05:ca:d4:09:01
                  mtu: 1500
                  set-name: ens4f1
          vlans:
              bond-mgt.20:
              addresses:
                  - 192.168.0.10/24
                  id: 20
                  link: bond-mgt
                  mtu: 1500
          vlans:
              bond-mgt.21: // Enter the VLAN ID you verified on the console instead of 21.
              addresses:
                  - 192.168.0.20/24 // Set it to the local Subnet IP verified in the console.
                  id: 21    // Set to the VLAN ID verified in the console.
                  link: bond-mgt
                  mtu: 1500
      code block. Add Vlan and set IP
  2. Apply the changes to the system.

    Color mode
    # netplan apply
    # netplan apply
    Code block. Reflect changes

  3. Check the interface status.

    Color mode
    # ip a
    or
    # bash /usr/local/bin/ip.sh
    # ip a
    or
    # bash /usr/local/bin/ip.sh
    Code block. Interface lookup

Linux – Configuring Subnet on CentOS/Red Hat

CentOS/Red Hat operating system, after adding a local Subnet, follow these steps to configure the network.

Caution
When adding a local Subnet or configuring the network incorrectly, be careful as the IP information in use may be deleted.
  1. Check the Bond Name for the local Subnet.
    Color mode
    # sh /usr/local/bin/ip.sh
    # sh /usr/local/bin/ip.sh
    code block. Verify bonding
  2. Modify the following command and execute it.
    Color mode
    #!/usr/bin/bash
    
    IP_ADDR="10.1.1.3/24"   // Set the local Subnet IP as observed in the Console.
    VLAN_ID="7"             // Set the Vlan ID as observed in the console.
    
    BOND_NAME="bond-mgt" // 1. Set the Bond Name you confirmed.
    
    # add vlan
    nmcli conn add type vlan ifname "${BOND_NAME}.${VLAN_ID}" con-name "${BOND_NAME}.${VLAN_ID}" id ${VLAN_ID} dev ${BOND_NAME}
    nmcli con  mod ${BOND_NAME}.${VLAN_ID} con-name "Vlan ${BOND_NAME}.${VLAN_ID}"
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv4.addresses ${IP_ADDR}
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv4.method manual
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv6.method "ignore"
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" connect.autoconnect yes
    nmcli con  up  "Vlan ${BOND_NAME}.${VLAN_ID}"
    
    nmcli      device reapply ${BOND_NAME}.${VLAN_ID}
    #!/usr/bin/bash
    
    IP_ADDR="10.1.1.3/24"   // Set the local Subnet IP as observed in the Console.
    VLAN_ID="7"             // Set the Vlan ID as observed in the console.
    
    BOND_NAME="bond-mgt" // 1. Set the Bond Name you confirmed.
    
    # add vlan
    nmcli conn add type vlan ifname "${BOND_NAME}.${VLAN_ID}" con-name "${BOND_NAME}.${VLAN_ID}" id ${VLAN_ID} dev ${BOND_NAME}
    nmcli con  mod ${BOND_NAME}.${VLAN_ID} con-name "Vlan ${BOND_NAME}.${VLAN_ID}"
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv4.addresses ${IP_ADDR}
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv4.method manual
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv6.method "ignore"
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" connect.autoconnect yes
    nmcli con  up  "Vlan ${BOND_NAME}.${VLAN_ID}"
    
    nmcli      device reapply ${BOND_NAME}.${VLAN_ID}
    Code block. IP configuration script
  3. Check the interface status.
    Color mode
    # ip a
    or
    # bash /usr/local/bin/ip.sh
    # ip a
    or
    # bash /usr/local/bin/ip.sh
    Code block. Interface lookup

Configuring Subnet on Windows

After adding a local Subnet on the Windows operating system, follow these steps to configure the network.

  1. Windows Start icon, right-click it, then run the Windows PowerShell(Administrator) program.

  2. Check the Teaming name for the local Subnet.

    Color mode
    PS C:\> Get-NetAdapter
    PS C:\> Get-NetAdapter
    code block. Check Windows interface

  3. After adding a new VLAN, set the IP.

    • Enter the Teaming name confirmed in step 2, and the Vlan ID and local Subnet IP confirmed in the Console.
      Color mode
      PS C:\> Add-NetLbfoTeamNIC -Team bond_bond-mgt -VlanID 20 -Name bond-mgt.20
      PS C:\> Get-NetAdapter
      PS C:\> netsh interface ip set address bond-mgt.20 static 192.168.0.10/24
      PS C:\> Add-NetLbfoTeamNIC -Team bond_bond-mgt -VlanID 20 -Name bond-mgt.20
      PS C:\> Get-NetAdapter
      PS C:\> netsh interface ip set address bond-mgt.20 static 192.168.0.10/24
      Code block. Create Teaming
  4. In the Windows Run menu, execute ncpa.cpl to check the interface status.

    Figure

Add second connection (kr-west, kr-south)

If there is a local subnet connected to the Bare Metal Server, the guide for the second additional connection is below.

Because a Bonding was already created when connecting the first local Subnet, there is no procedure to create Bonding when connecting the second local Subnet.

Please refer to the details below.

Notice
This guide can be applied commonly to kr-west and kr-south.

Linux - Setting up Subnet on Ubuntu

To add a local Subnet and configure the network on an Ubuntu operating system, follow these steps.

  1. After adding a new VLAN, set the IP.

    • Replace the example code’s ID and IP with the assigned ID and IP.
      Color mode
      [root@localhost ~]# vi /etc/netplan/50-cloud-init.yaml
      network:
          bonds:
              bond-mgt:
                  interfaces:
                  - ens2f1
                  - ens4f1
                  mtu: 1500
                  parameters:
                      mii-monitor-interval: 100
                      mode: active-backup
                      transmit-hash-policy: layer2
          ethernets:
              ens2f1:
                  match:
                  macaddress: 68:05:ca:d4:09:91
                  mtu: 1500
                  set-name: ens2f1
              ens4f1:
                  match:
                  macaddress: 68:05:ca:d4:09:01
                  mtu: 1500
                  set-name: ens4f1
          vlans:
              bond-mgt.20:
              addresses:
                  - 192.168.0.10/24
                  id: 20
                  link: bond-mgt
                  mtu: 1500
          vlans:
              bond-mgt.21: // Enter the VLAN ID you verified on the console instead of 21.
              addresses:
                  - 192.168.0.20/24 // Set it to the local Subnet IP verified in the console.
                  id: 21    // Set to the VLAN ID verified in the console.
                  link: bond-mgt
                  mtu: 1500
      [root@localhost ~]# vi /etc/netplan/50-cloud-init.yaml
      network:
          bonds:
              bond-mgt:
                  interfaces:
                  - ens2f1
                  - ens4f1
                  mtu: 1500
                  parameters:
                      mii-monitor-interval: 100
                      mode: active-backup
                      transmit-hash-policy: layer2
          ethernets:
              ens2f1:
                  match:
                  macaddress: 68:05:ca:d4:09:91
                  mtu: 1500
                  set-name: ens2f1
              ens4f1:
                  match:
                  macaddress: 68:05:ca:d4:09:01
                  mtu: 1500
                  set-name: ens4f1
          vlans:
              bond-mgt.20:
              addresses:
                  - 192.168.0.10/24
                  id: 20
                  link: bond-mgt
                  mtu: 1500
          vlans:
              bond-mgt.21: // Enter the VLAN ID you verified on the console instead of 21.
              addresses:
                  - 192.168.0.20/24 // Set it to the local Subnet IP verified in the console.
                  id: 21    // Set to the VLAN ID verified in the console.
                  link: bond-mgt
                  mtu: 1500
      code block. Add Vlan and set IP
  2. Apply the changes to the system.

    Color mode
    # netplan apply
    # netplan apply
    Code block. Reflect changes

  3. Check the interface status.

    Color mode
    # ip a
    or
    # bash /usr/local/bin/ip.sh
    # ip a
    or
    # bash /usr/local/bin/ip.sh
    Code block. Interface lookup

Linux – Configuring Subnet on CentOS/Red Hat

After adding a local Subnet on CentOS/Red Hat operating systems, follow the steps below to configure the network.

Caution
When adding a local Subnet or configuring the network incorrectly, be careful as the IP information in use may be deleted.
  1. Check the Bond Name for the local Subnet.
    Color mode
    # sh /usr/local/bin/ip.sh
    # sh /usr/local/bin/ip.sh
    code block. Verify bonding
  2. Modify the following command and execute it.
    Color mode
    #!/usr/bin/bash
    
    IP_ADDR="10.1.1.3/24"   // Set the local Subnet IP as observed in the Console.
    VLAN_ID="7"             // Set the Vlan ID as observed in the console.
    
    BOND_NAME="bond-mgt" // 1. Set the Bond Name you confirmed.
    
    # add vlan
    nmcli conn add type vlan ifname "${BOND_NAME}.${VLAN_ID}" con-name "${BOND_NAME}.${VLAN_ID}" id ${VLAN_ID} dev ${BOND_NAME}
    nmcli con  mod ${BOND_NAME}.${VLAN_ID} con-name "Vlan ${BOND_NAME}.${VLAN_ID}"
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv4.addresses ${IP_ADDR}
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv4.method manual
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv6.method "ignore"
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" connect.autoconnect yes
    nmcli con  up  "Vlan ${BOND_NAME}.${VLAN_ID}"
    
    nmcli      device reapply ${BOND_NAME}.${VLAN_ID}
    #!/usr/bin/bash
    
    IP_ADDR="10.1.1.3/24"   // Set the local Subnet IP as observed in the Console.
    VLAN_ID="7"             // Set the Vlan ID as observed in the console.
    
    BOND_NAME="bond-mgt" // 1. Set the Bond Name you confirmed.
    
    # add vlan
    nmcli conn add type vlan ifname "${BOND_NAME}.${VLAN_ID}" con-name "${BOND_NAME}.${VLAN_ID}" id ${VLAN_ID} dev ${BOND_NAME}
    nmcli con  mod ${BOND_NAME}.${VLAN_ID} con-name "Vlan ${BOND_NAME}.${VLAN_ID}"
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv4.addresses ${IP_ADDR}
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv4.method manual
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" ipv6.method "ignore"
    nmcli con  mod "Vlan ${BOND_NAME}.${VLAN_ID}" connect.autoconnect yes
    nmcli con  up  "Vlan ${BOND_NAME}.${VLAN_ID}"
    
    nmcli      device reapply ${BOND_NAME}.${VLAN_ID}
    Code block. IP configuration script
  3. Check the interface status.
    Color mode
    # ip a
    or
    # bash /usr/local/bin/ip.sh
    # ip a
    or
    # bash /usr/local/bin/ip.sh
    Code block. Interface lookup

Configuring Subnet on Windows

After adding a local Subnet on the Windows operating system, follow these steps to configure the network.

  1. Windows Start icon, right-click it, then run the Windows PowerShell(Administrator) program.

  2. Check the Teaming name for the local Subnet.

    Color mode
    PS C:\> Get-NetAdapter
    PS C:\> Get-NetAdapter
    code block. Check Windows interface

  3. After adding a new VLAN, configure the IP.

    • Enter the Teaming name confirmed in step 2, the Vlan ID confirmed in the Console, and the local Subnet IP.
      Color mode
      PS C:\> Add-NetLbfoTeamNIC -Team bond_bond-mgt -VlanID 20 -Name bond-mgt.20
      PS C:\> Get-NetAdapter
      PS C:\> netsh interface ip set address bond-mgt.20 static 192.168.0.10/24
      PS C:\> Add-NetLbfoTeamNIC -Team bond_bond-mgt -VlanID 20 -Name bond-mgt.20
      PS C:\> Get-NetAdapter
      PS C:\> netsh interface ip set address bond-mgt.20 static 192.168.0.10/24
      Code block. Create Teaming
  4. In the Windows Run menu, execute ncpa.cpl to check the interface status.

    Figure

Change IP

The IP can be changed to carry out migration, server replacement, and similar tasks.

Caution
  • If you proceed with changing the IP, you will no longer be able to communicate using that IP, and you cannot cancel the IP change while it is in progress.
  • If the server is running the Load Balancer service, you must delete the old IP from the LB server group and directly add the new IP as a member of the LB server group.
  • Servers using Public NAT, Privat NAT must disable and reconfigure Public NAT, Privat NAT after an IP change.
    • If you are using Public NAT and Privat NAT, first disable the use of Public NAT and Privat NAT, complete the IP change, and then reconfigure.
    • Whether to use Public NAT and Privat NAT can be changed by clicking the Edit button for Public NAT IP and Privat NAT on the Bare Metal Server Details page.

Follow these steps to change the IP.

  1. All Services > Compute > Bare Metal Server Click the menu. 1. Go to the Service Home page of the Bare Metal Server.

  2. On the Service Home page, click the Bare Metal Server menu. 2. Go to the Bare Metal Server List page.

  3. Bare Metal Server List page, click the server whose IP you want to change. Navigate to the Bare Metal Server Detail page.

  4. On the Bare Metal Server Details page, click the Edit button next to the IP field.

  5. When the popup notifying IP modification opens, click the Confirm button. 5. IP Change The popup window opens.

  6. IP Change popup window’s Step 1, Step 2, Step 3 tasks should be performed sequentially.

    Notice
    • When changing the IP, the detailed configuration method for the IP change step varies depending on the subnet of the IP to be changed. * Be sure to refer to the following example and proceed with the tasks step by step.
    • When each step is completed successfully, the task status in the upper right corner is displayed as Completed, and you can proceed to the next step.
    • When performing the final check of Step 3, it is recommended to restart the server before proceeding with the inspection.

  7. After confirming that all tasks have completed successfully, click the Confirm button.

Change to an IP in the same Subnet

This explains how to configure IP settings per operating system when the IP to be changed uses the same subnet.

Linux – centos/redhat operating system

Step 1

Follow the steps below and proceed with Step 1.

  1. Select the Subnet to modify.
  2. Enter the IP to change.
  3. Click the IP Allocation Request button.
  4. When a pop-up notifying you of an IP change opens, click the Confirm button.
    • When the task completes successfully, the task status in the upper right corner will be displayed as Completed.
      Caution
      If you proceed with the IP allocation request of Step 1, you cannot cancel or restore the IP change.

Step 2

Follow the steps below to perform Step 2.

  1. For the IP change operation, connect to the target server using the NAT IP.

    Notice
    To prevent communication failures during operation, it is recommended to connect through another Virtual Server or Bare Metal Server created in the same subnet.

  2. Enter the assigned IP from Step 1 and set the new IP on the server.

    • In the following example, replace 172.17.34.150 with the assigned IP address.
    • After checking the information of the Interface you want to change on the server, replace it with bond-srv.9 in the following example.
      Color mode
      # nmcli con mod "Vlan bond-srv.9" ipv4.addresses 172.17.34.150/24
      # nmcli con mod "Vlan bond-srv.9" ipv4.method manual
      # nmcli  device reapply bond-srv.9
      # nmcli con mod "Vlan bond-srv.9" ipv4.addresses 172.17.34.150/24
      # nmcli con mod "Vlan bond-srv.9" ipv4.method manual
      # nmcli  device reapply bond-srv.9
      Code block. IP settings to modify
      Notice
      • Setting the IP disconnects the terminal session.
      • Step 2 After completing the task, if the task status changes to Completed, you can reconnect to the terminal.
  3. When all tasks are completed, select the task completion checkbox for Step 2 in the IP 변경 popup window.

    • When the task completes successfully, the task status in the upper right corner will be displayed as Completed.
      Notice
      • If the task status of Step 2 has changed to Completed but you still have issues with terminal access, go to the All Services > Management > Support Center Contact Us menu and contact us.

Step 3

Proceed with Step 3 according to the following procedure.

  1. Connect to the server to be changed using the NAT IP and check its communication status.

    • Use the following command to verify whether any pre‑change configuration information remains and whether the change was applied correctly. * If you can successfully connect to the server targeted for IP change, the changed IP is in normal communication state.
      Color mode
      # bash /usr/local/bin/ip.sh
      # bash /usr/local/bin/ip.sh
      Code block. Communication status check
      Reference
      The NAT IP does not change.
  2. After all tasks are completed, restart the server and then perform a final check.

    Reference
    It is recommended to perform the final check after restarting the server.

  3. If the final inspection shows no issues, select the work‑completion checkbox for Step 3 in the IP change popup.

Linux – Ubuntu operating system

Step 1

Follow the steps below and proceed with Step 1.

  1. Select the Subnet to modify.
  2. Enter the IP to change.
  3. Click the IP Allocation Request button.
  4. When a pop-up notifying you of an IP change opens, click the Confirm button.
    • When the task completes successfully, the task status in the upper right corner will be displayed as Completed.
      Caution
      If you proceed with the IP allocation request of Step 1, you cannot cancel or restore the IP change.

Step 2

Follow the steps below to perform Step 2.

  1. For the IP change operation, connect to the target server using the NAT IP.

    Notice
    To prevent communication failures during operation, it is recommended to connect through another Virtual Server or Bare Metal Server created in the same subnet.

  2. Enter the assigned IP from Step 1 and set the new IP on the server.

    • In the following example, replace 172.17.34.150/24 with the assigned IP address.
    • After checking the information of the Interface you want to change on the server, replace it with bond-srv.9 in the following example.
      Color mode
      [root@localhost ~]# vi /etc/netplan/50-cloud-init.yaml
      network:
          bonds:
          ......................     Omitted
          ethernets:
          ......................     Omitted
          vlans:
              bond-srv.9:
              addresses:
                  - 172.17.34.150/24   # Enter the IP assigned in Step1.
                  gateway4: 172.17.34.2
                  id: 9
                  link: bond-srv
                  mtu: 1500
              bond-srv.350:
                  addresses:
                  - 172.16.87.150/24
                  routes:
                  - to: 172.17.87.0/24
                    via: 172.16.87.1
      - to: 172.17.87.0/24
                    via: 172.16.87.1
                  id: 350
                  link: bond-srv
      [root@localhost ~]# vi /etc/netplan/50-cloud-init.yaml
      network:
          bonds:
          ......................     Omitted
          ethernets:
          ......................     Omitted
          vlans:
              bond-srv.9:
              addresses:
                  - 172.17.34.150/24   # Enter the IP assigned in Step1.
                  gateway4: 172.17.34.2
                  id: 9
                  link: bond-srv
                  mtu: 1500
              bond-srv.350:
                  addresses:
                  - 172.16.87.150/24
                  routes:
                  - to: 172.17.87.0/24
                    via: 172.16.87.1
      - to: 172.17.87.0/24
                    via: 172.16.87.1
                  id: 350
                  link: bond-srv
      Code block. IP settings to modify
  3. Use the Netplan apply command to apply the changes to the system.

    Color mode
    [root@localhost ~]# netplan apply
    [root@localhost ~]# netplan apply
    Code block. Run Netplan apply
    Notice
    • Setting the IP disconnects the terminal session.
    • Step 2 After completing the task, if the task status changes to Completed, you can reconnect to the terminal.

  4. When all tasks are completed, select the task completion checkbox for Step 2 in the IP Change popup.

    • When the task completes successfully, the task status in the upper right corner will be displayed as Completed.
      Notice
      • If the task status of Step 2 has changed to Completed but you still have issues with terminal access, go to the All Services > Management > Support Center Contact Us menu and submit an inquiry.

Step 3

Proceed with Step 3 according to the following procedure.

  1. Connect to the server to be changed using the NAT IP and check its communication status.

    • Use the following command to verify whether any pre‑change configuration information remains and whether the change was applied correctly. * If you can successfully connect to the server targeted for IP change, the new IP is operating normally.
      Color mode
      # bash /usr/local/bin/ip.sh
      # bash /usr/local/bin/ip.sh
      Code block. Communication status check
      Reference
      The NAT IP does not change.
  2. After all tasks are completed, restart the server and then perform a final check.

    Reference
    It is recommended to perform the final check after restarting the server.

  3. If there are no issues in the final inspection results, select the work completion checkbox for Step 3 in the IP Change popup window.

Windows operating system

Step 1

Follow the steps below and proceed with Step 1.

  1. Select the Subnet to modify.
  2. Enter the IP to change.
  3. Click the IP Allocation Request button.
  4. When the popup notifying IP change verification opens, click the Confirm button.
    • When the task completes successfully, the task status in the upper right corner will be displayed as Completed.
      Caution
      If you proceed with the IP allocation request of Step 1, you cannot cancel or restore the IP change.

Step 2

Follow the steps below to perform Step 2.

  1. For the IP change operation, connect to the target server using the NAT IP.

    Notice
    To prevent communication failures during operation, it is recommended to connect through another Virtual Server or Bare Metal Server created in the same subnet.

  2. Windows Start icon, right‑click it, then run Windows PowerShell(Administrator).

  3. Enter the assigned IP from Step 1 and set the new IP on the server.

    • In the following example, replace 172.17.34.150 with the assigned IP address.
      Color mode
      PS C:\> netsh interface ip set address "bond-srv.20" static 172.17.34.150 255.255.255.0
      PS C:\> netsh interface ip set address "bond-srv.20" static 172.17.34.150 255.255.255.0
      Code block. IP settings to modify
      Notice
      • Setting the IP disconnects the terminal session.
      • Step 2 After completing the task, if the task status changes to Completed, you can reconnect to the terminal.
  4. When all tasks are completed, select the task completion checkbox for Step 2 in the IP 변경 popup window.

    • When the task completes successfully, the task status in the upper right corner will be displayed as Completed.
      Notice
      • If the task status of Step 2 has changed to Completed but you still have issues with terminal access, go to the All Services > Management > Support Center Contact Us menu and contact us.

Step 3

Proceed with Step 3 according to the following procedure.

  1. Connect to the server to be changed using the NAT IP and check its communication status.

    • Use the following command to verify whether any pre‑change configuration information remains and whether the change was applied correctly. * If you can successfully connect to the server targeted for IP change, the changed IP is in normal communication state.
      Color mode
      PS C:\> Get-NetIPAddress | Format-Table
      PS C:\> Get-NetIPAddress | Format-Table
      Code block. Communication status check
      Reference
      The NAT IP does not change.
  2. After all tasks are completed, restart the server and then perform a final check.

    Reference
    It is recommended to perform the final check after restarting the server.

  3. If there are no issues in the final inspection results, select the work completion checkbox for Step 3 in the IP Change popup window.

Change to IP of another Subnet

This explains how to configure IP settings for each operating system when the IP to be changed uses a different subnet.

Linux – centos/redhat operating system

Step 1

Follow the steps below and proceed with Step 1.

  1. Select the Subnet to modify.
  2. Enter the IP to change.
  3. Click the IP Allocation Request button.
  4. When the popup notifying IP change verification opens, click the Confirm button.
    • When the operation completes successfully, Vlan ID check, Default Gateway check information is displayed, and the operation status in the upper right corner shows Completed.
      Caution
      If you proceed with the IP allocation request of Step 1, you cannot cancel or restore the IP change.

Step 2

Follow the steps below to perform Step 2.

  1. For the IP change operation, connect to the target server using the NAT IP.

    Notice
    To prevent communication failures during operation, it is recommended to connect through another Virtual Server or Bare Metal Server created in the same subnet.

  2. Add a new VLAN and configure the IP to add the IP to the server.

    • Add VLAN: Create the interface of the Vlan ID identified in Step 1. * In the following example, enter the assigned ID instead of 20.
    • IP configuration: Enter the IP assigned in Step 1. * In the following example, replace 192.168.0.10/24 with the assigned IP address.
      Color mode
      # nmcli conn add type vlan ifname "bond-srv.20" con-name "bond-srv.20" id 20 dev bond-srv
      # nmcli con mod bond-srv.20 con-name "Vlan bond-srv.20"
      # nmcli con mod "Vlan bond-srv.20" ipv4.addresses 192.168.0.10/24
      # nmcli con mod "Vlan bond-srv.20" ipv4.method manual
      # nmcli con mod "Vlan bond-srv.20" ipv6.method "ignore"
      # nmcli con up  "Vlan bond-srv.20"
      # nmcli conn add type vlan ifname "bond-srv.20" con-name "bond-srv.20" id 20 dev bond-srv
      # nmcli con mod bond-srv.20 con-name "Vlan bond-srv.20"
      # nmcli con mod "Vlan bond-srv.20" ipv4.addresses 192.168.0.10/24
      # nmcli con mod "Vlan bond-srv.20" ipv4.method manual
      # nmcli con mod "Vlan bond-srv.20" ipv6.method "ignore"
      # nmcli con up  "Vlan bond-srv.20"
      Code block. IP settings to modify
  3. Set the default gateway for the new VLAN.

    • Default gateway configuration: Enter the Default gateway IP assigned in Step 1. * In the following example, replace 192.168.0.1 with the assigned Default gateway IP.
      Color mode
      # nmcli con mod "Vlan bond-srv.20"  ipv4.gateway 192.168.0.1
      # nmcli device reapply bond-srv.20
      # nmcli con mod "Vlan bond-srv.20"  ipv4.gateway 192.168.0.1
      # nmcli device reapply bond-srv.20
      Code block. IP settings to modify
      Notice
      • If you set a Default Gateway on a new VLAN, the terminal session gets disconnected.
      • Step 2 After completing the task, if the task status changes to Completed, you can reconnect to the terminal.
  4. When all tasks are completed, select the task completion checkbox for Step 2 in the IP 변경 popup window.

    • When the task completes successfully, the task status in the upper right corner will be displayed as Completed.
      Notice
      • If the task status of Step 2 has changed to Completed but you still experience problems with terminal access, navigate to the All Services > Management > Support Center Contact Us menu and submit an inquiry.

Step 3

Proceed with Step 3 according to the following procedure.

  1. Connect to the server subject to IP change using a NAT IP.

  2. Verify the Default Gateway IP of the existing (pre-change) interface, then delete it.

    • In the following example, replace 192.168.10.1 with the IP you verified.
      Color mode
      # ip route del   default  via 192.168.10.1
      # ip route del   default  via 192.168.10.1
      Code block. Delete the Default Gateway IP of the existing interface
  3. Connect to the server to be changed using the NAT IP and check its communication status.

    • Use the following command to verify whether any pre‑change configuration information remains and whether the changes were applied correctly. * If you can successfully connect to the server targeted for IP change, the changed IP is in normal communication state.
      Color mode
      # netstat nr
      # bash /usr/local/bin/ip.sh
      # netstat nr
      # bash /usr/local/bin/ip.sh
      Code block. Communication status check
      Reference
      The NAT IP does not change.
  4. Check the VLAN information of the existing IP and then delete it from the server.

    • Enter the verified ID in place of 30 in the following example.
      Color mode
      # nmcli con delete "Vlan bond-srv.30"
      # nmcli con delete "Vlan bond-srv.30"
      Code block. Delete the VLAN information of the existing IP.
  5. After all tasks are completed, restart the server and then perform a final check.

    Reference
    It is recommended to perform the final check after restarting the server.

  6. If the final inspection results show no issues, select the work‑completion checkbox for Step 3 in the IP Change popup window.

Linux – Ubuntu operating system

Step 1

Follow the steps below and proceed with Step 1.

  1. Select the Subnet to modify.
  2. Enter the IP to change.
  3. Click the IP Allocation Request button.
  4. When a popup that notifies IP change verification opens, click the Confirm button.
    • When the operation completes successfully, Vlan ID check, Default Gateway check information is displayed, and the operation status in the upper right corner shows Completed.
      Caution
      If you proceed with the IP allocation request of Step 1, you cannot cancel or restore the IP change.

Step 2

Follow the steps below to perform Step 2.

  1. For the IP change operation, connect to the target server using the NAT IP.

    Notice
    To prevent communication failures during operation, it is recommended to connect through another Virtual Server or Bare Metal Server created in the same subnet.

  2. Add a new VLAN and set the IP and Default Gateway to add the IP to the server.

    • In the following example, this is the part where content is added at the bottom of the Step 1 task description.
    • In the following example, enter the assigned ID and IP instead of ID and IP.
      Color mode
      [root@localhost ~]# vi /etc/netplan/50-cloud-init.yaml
      network:
          bonds:
          ......................     Omitted
          ethernets:
          ......................     Omitted
          vlans:
              bond-srv.9:
              addresses:
                  - 172.17.34.150/24
      
                  gateway4: 172.17.34.2
                  id: 9
                  link: bond-srv
                  mtu: 1500
              bond-srv.350:
                  addresses:
                  - 172.16.87.150/24
                  routes:
                  - to: 172.17.87.0/24
                    via: 172.16.87.1
      - to: 172.17.87.0/24
                    via: 172.16.87.1
                  id: 350
                  link: bond-srv
      
      # Create the interface for the Vlan ID identified in Step1.
      # Enter the IP assigned in Step1.
      # Enter the Default gateway IP assigned in Step1.
      bond-srv.20:
              addresses:
                  - 192.168.0.10/24
                  gateway4: 192.168.0.1
                  id: 20
                  link: bond-srv
                  mtu: 1500
      [root@localhost ~]# vi /etc/netplan/50-cloud-init.yaml
      network:
          bonds:
          ......................     Omitted
          ethernets:
          ......................     Omitted
          vlans:
              bond-srv.9:
              addresses:
                  - 172.17.34.150/24
      
                  gateway4: 172.17.34.2
                  id: 9
                  link: bond-srv
                  mtu: 1500
              bond-srv.350:
                  addresses:
                  - 172.16.87.150/24
                  routes:
                  - to: 172.17.87.0/24
                    via: 172.16.87.1
      - to: 172.17.87.0/24
                    via: 172.16.87.1
                  id: 350
                  link: bond-srv
      
      # Create the interface for the Vlan ID identified in Step1.
      # Enter the IP assigned in Step1.
      # Enter the Default gateway IP assigned in Step1.
      bond-srv.20:
              addresses:
                  - 192.168.0.10/24
                  gateway4: 192.168.0.1
                  id: 20
                  link: bond-srv
                  mtu: 1500
      Code block. IP settings to modify
  3. Use the Netplan apply command to apply the changes to the system.

    Color mode
    [root@localhost ~]# netplan apply
    [root@localhost ~]# netplan apply
    Code block. Run Netplan apply
    Notice
    • If you set a new Default Gateway, the terminal session will be disconnected.
    • Step 2 After completing the task, if the task status changes to Completed, you can reconnect to the terminal.

  4. When all tasks are completed, select the task completion checkbox for Step 2 in the IP 변경 popup window.

    • When the task completes successfully, the task status in the upper right corner will be displayed as Completed.
      Notice
      • If the task status of Step 2 has changed to Completed but you still experience problems with terminal access, navigate to the All Services > Management > Support Center Contact Us menu and submit an inquiry.

Step 3

Proceed with Step 3 according to the following procedure.

  1. Connect to the server subject to IP change using a NAT IP.

  2. Verify the Default Gateway IP of the existing (pre-change) interface, then delete it.

    • In the following example, the Delete this line row is the part that gets deleted.
      Color mode
      [root@localhost ~]# vi /etc/netplan/50-cloud-init.yaml
      network:
          bonds:
          ......................     Omitted
          ethernets:
          ......................     Omitted
          vlans:
              bond-srv.9:
              addresses:
                  - 172.17.34.150/24
                  gateway4: 172.17.34.2    #Delete this line
                  id: 9
                  link: bond-srv
                  mtu: 1500
              bond-srv.350:
                  addresses:
                  - 172.16.87.150/24
                  routes:
                  - to: 172.17.87.0/24
                    via: 172.16.87.1
      - to: 172.17.87.0/24
                    via: 172.16.87.1
                  id: 350
                  link: bond-srv
      
      bond-srv.20:
              addresses:
                  - 192.168.0.10/24
                  gateway4: 192.168.0.1
                  id: 20
                  link: bond-srv
                  mtu: 1500
      [root@localhost ~]# vi /etc/netplan/50-cloud-init.yaml
      network:
          bonds:
          ......................     Omitted
          ethernets:
          ......................     Omitted
          vlans:
              bond-srv.9:
              addresses:
                  - 172.17.34.150/24
                  gateway4: 172.17.34.2    #Delete this line
                  id: 9
                  link: bond-srv
                  mtu: 1500
              bond-srv.350:
                  addresses:
                  - 172.16.87.150/24
                  routes:
                  - to: 172.17.87.0/24
                    via: 172.16.87.1
      - to: 172.17.87.0/24
                    via: 172.16.87.1
                  id: 350
                  link: bond-srv
      
      bond-srv.20:
              addresses:
                  - 192.168.0.10/24
                  gateway4: 192.168.0.1
                  id: 20
                  link: bond-srv
                  mtu: 1500
      Code block. Delete the Default Gateway IP of the existing interface
  3. Connect to the server to be changed using the NAT IP and check its communication status.

    • Use the following command to verify whether any pre‑change configuration information remains and whether the change was applied correctly. * If you can successfully connect to the server targeted for IP change, the changed IP is in normal communication state.
      Color mode
      # netstat nr
      # bash /usr/local/bin/ip.sh
      # netstat nr
      # bash /usr/local/bin/ip.sh
      Code block. Communication status check
      Reference
      The NAT IP does not change.
  4. Delete the existing IP.

    • In the following example, the Delete this line row is the part that gets deleted.
      Color mode
      [root@localhost ~]# vi /etc/netplan/50-cloud-init.yaml
      network:
          bonds:
          ......................     Omitted
          ethernets:
          ......................     Omitted
          vlans:
              bond-srv.9:                   #Delete this line
              addresses:                    #Delete this line
                  - 172.17.34.150/24        # Delete this line
                  gateway4: 172.17.34.2     #Delete this line
                  id: 9                     # Delete this line
                  link: bond-srv            #Delete this line
                  mtu: 1500                 #Delete this line
              bond-srv.350:
                  addresses:
                  - 172.16.87.150/24
                  routes:
                  - to: 172.17.87.0/24
                    via: 172.16.87.1
      - to: 172.17.87.0/24
                    via: 172.16.87.1
                  id: 350
                  link: bond-srv
      
      bond-srv.20:
              addresses:
                  - 192.168.0.10/24
                  gateway4: 192.168.0.1
                  id: 20
                  link: bond-srv
                  mtu: 1
      [root@localhost ~]# vi /etc/netplan/50-cloud-init.yaml
      network:
          bonds:
          ......................     Omitted
          ethernets:
          ......................     Omitted
          vlans:
              bond-srv.9:                   #Delete this line
              addresses:                    #Delete this line
                  - 172.17.34.150/24        # Delete this line
                  gateway4: 172.17.34.2     #Delete this line
                  id: 9                     # Delete this line
                  link: bond-srv            #Delete this line
                  mtu: 1500                 #Delete this line
              bond-srv.350:
                  addresses:
                  - 172.16.87.150/24
                  routes:
                  - to: 172.17.87.0/24
                    via: 172.16.87.1
      - to: 172.17.87.0/24
                    via: 172.16.87.1
                  id: 350
                  link: bond-srv
      
      bond-srv.20:
              addresses:
                  - 192.168.0.10/24
                  gateway4: 192.168.0.1
                  id: 20
                  link: bond-srv
                  mtu: 1
      Code block. Delete existing IP
  5. Apply the changes to the system.

    Color mode
    [root@localhost ~]# netplan apply
    [root@localhost ~]#  ip link delete bond-srv.9 # Additional steps when deleting VLAN
    [root@localhost ~]# netplan apply
    [root@localhost ~]#  ip link delete bond-srv.9 # Additional steps when deleting VLAN
    Code block. Apply changes

  6. After all tasks are completed, restart the server and then perform a final check.

Reference
It is recommended to perform the final check after restarting the server.
  1. If the final inspection results show no issues, select the work‑completion checkbox for Step 3 in the IP Change popup window.

Windows operating system

Step 1

Follow the steps below and proceed with Step 1.

  1. Select the Subnet to modify.
  2. Enter the IP to change.
  3. Click the IP Allocation Request button.
  4. When the popup indicating IP change verification opens, click the Confirm button.
    • When the operation completes successfully, Vlan ID check, Default Gateway check information is displayed, and the operation status in the upper right corner shows Completed.
      Caution
      If you proceed with the IP allocation request of Step 1, you cannot cancel or restore the IP change.

Step 2

Follow the steps below to perform Step 2.

  1. For the IP change operation, connect to the target server using the NAT IP.

    Notice
    To prevent communication failures during operation, it is recommended to connect through another Virtual Server or Bare Metal Server created in the same subnet.

  2. Windows Start icon, right-click, then run Windows PowerShell(Administrator).

  3. Add a VLAN and configure the IP and default gateway.

    • Add VLAN: Create the interface of the Vlan ID identified in Step 1. * In the following example, enter the assigned ID instead of 20.
    • IP configuration: Enter the IP assigned in Step 1. * In the following example, replace 46 with the ifindex obtained using Get‑NetAdapter, and replace 192.168.0.10 with the assigned IP address.
    • Default gateway configuration: Enter the Default gateway IP assigned in Step 1. * In the following example, replace 192.168.0.1 with the assigned Default gateway IP.
      Color mode
      PS C:\> Add-NetLbfoTeamNIC -Team bond_bond-srv -VlanID 20 -Name bond-srv.20 -Confirm:$false
      PS C:\> Get-NetAdapter
      PS C:\> New-NetIPAddress -InterfaceIndex 46 -IPAddress 192.168.0.10 -PrefixLength 24 defaultgateway 192.168.0.1
      PS C:\> Add-NetLbfoTeamNIC -Team bond_bond-srv -VlanID 20 -Name bond-srv.20 -Confirm:$false
      PS C:\> Get-NetAdapter
      PS C:\> New-NetIPAddress -InterfaceIndex 46 -IPAddress 192.168.0.10 -PrefixLength 24 defaultgateway 192.168.0.1
      Code block. IP settings to modify
      Notice
      • If you set a new Default Gateway, the terminal session will be disconnected.
      • Step 2 After completing the task, if the task status changes to Completed, you can reconnect to the terminal.
  4. When all tasks are completed, select the task completion checkbox for Step 2 in the IP 변경 popup window.

    • When the task completes successfully, the task status in the upper right corner will be displayed as Completed.
      Notice
      • If the task status of Step 2 has changed to Completed but you still experience problems with terminal access, navigate to the All Services > Management > Support Center Contact Us menu and submit an inquiry.

Step 3

Proceed with Step 3 according to the following procedure.

  1. Connect to the server subject to IP change using a NAT IP.

  2. Run the interface index (ifindex) to check the existing Default Gateway IP.

    Color mode
    PS C:\> Get-NetAdapter
    Name                      InterfaceDescription                    ifIndex Status       MacAddress             LinkSpeed
    ----                      --------------------                    ------- ------       ----------             ---------
    bond-srv.9                Microsoft Network Adapter Multiple...#4      30 Up           40-A6-B7-27-96-D5        50 Gbps
    bond-srv                  Microsoft Network Adapter Multiple...#3      19 Up           40-A6-B7-27-96-D5        50 Gbps
    bond-iscsi                Microsoft Network Adapter Multiple...#2      18 Up           40-A6-B7-27-96-D4        50 Gbps
    bond-backup               Microsoft Network Adapter Multiplexo... 22 Up           68-05-CA-C9-EB-88        20 Gbps
    eno2                      Intel(R) Ethernet Connection X722 fo... 12 Disabled     38-68-DD-36-A0-59         1 Gbps
    ens3f0                    Intel(R) Ethernet Network Adapter XX... 11 Up           40-A6-B7-27-96-D4        25 Gbps
    ………………………………………….. Omitted
    PS C:\> Get-NetAdapter
    Name                      InterfaceDescription                    ifIndex Status       MacAddress             LinkSpeed
    ----                      --------------------                    ------- ------       ----------             ---------
    bond-srv.9                Microsoft Network Adapter Multiple...#4      30 Up           40-A6-B7-27-96-D5        50 Gbps
    bond-srv                  Microsoft Network Adapter Multiple...#3      19 Up           40-A6-B7-27-96-D5        50 Gbps
    bond-iscsi                Microsoft Network Adapter Multiple...#2      18 Up           40-A6-B7-27-96-D4        50 Gbps
    bond-backup               Microsoft Network Adapter Multiplexo... 22 Up           68-05-CA-C9-EB-88        20 Gbps
    eno2                      Intel(R) Ethernet Connection X722 fo... 12 Disabled     38-68-DD-36-A0-59         1 Gbps
    ens3f0                    Intel(R) Ethernet Network Adapter XX... 11 Up           40-A6-B7-27-96-D4        25 Gbps
    ………………………………………….. Omitted
    code block. Run Get-NetAdapter
    Color mode
    PS C:\> get-netroute -ifindex 30
    
    ifIndex DestinationPrefix                              NextHop                                  RouteMetric PolicyStore
    ------- -----------------                              -------                                  ----------- -----------
    30      255.255.255.255/32                             0.0.0.0                                          256 ActiveStore
    30      224.0.0.0/4                                    0.0.0.0                                          256 ActiveStore
    30      172.17.35.0/24                                 172.17.35.1                                      256 ActiveStore
    30      172.17.34.255/32                               0.0.0.0                                          256 ActiveStore
    30      172.17.34.14/32                                0.0.0.0                                          256 ActiveStore
    30      172.17.34.0/24                                 0.0.0.0                                          256 ActiveStore
    30      0.0.0.0/0                                      172.17.34.1                                        1 ActiveStore
    PS C:\> get-netroute -ifindex 30
    
    ifIndex DestinationPrefix                              NextHop                                  RouteMetric PolicyStore
    ------- -----------------                              -------                                  ----------- -----------
    30      255.255.255.255/32                             0.0.0.0                                          256 ActiveStore
    30      224.0.0.0/4                                    0.0.0.0                                          256 ActiveStore
    30      172.17.35.0/24                                 172.17.35.1                                      256 ActiveStore
    30      172.17.34.255/32                               0.0.0.0                                          256 ActiveStore
    30      172.17.34.14/32                                0.0.0.0                                          256 ActiveStore
    30      172.17.34.0/24                                 0.0.0.0                                          256 ActiveStore
    30      0.0.0.0/0                                      172.17.34.1                                        1 ActiveStore
    Code block. Execute -ifindex

  3. Delete the existing Default Gateway IP.

    • In the following example, replace 30 with the ifindex obtained via Get-NetAdapter, and replace 172.17.34.1 with the IP you obtained.
      Color mode
      PS C:\> Remove-NetRoute -ifIndex 30 -DestinationPrefix 0.0.0.0/0 -NextHop 172.17.34.1 -Confirm:$false
      PS C:\> Remove-NetRoute -ifIndex 30 -DestinationPrefix 0.0.0.0/0 -NextHop 172.17.34.1 -Confirm:$false
      Code block. Delete Default Gateway IP
      Color mode
      PS C:\> get-netroute -ifindex 30
      
      ifIndex DestinationPrefix                              NextHop                                  RouteMetric PolicyStore
      ------- -----------------                              -------                                  ----------- -----------
      30      255.255.255.255/32                             0.0.0.0                                          256 ActiveStore
      30      224.0.0.0/4                                    0.0.0.0                                          256 ActiveStore
      30      172.17.34.255/32                               0.0.0.0                                          256 ActiveStore
      30      172.17.34.14/32                                0.0.0.0                                          256 ActiveStore
      30      172.17.34.0/24                                 0.0.0.0                                          256 ActiveStore
      PS C:\> get-netroute -ifindex 30
      
      ifIndex DestinationPrefix                              NextHop                                  RouteMetric PolicyStore
      ------- -----------------                              -------                                  ----------- -----------
      30      255.255.255.255/32                             0.0.0.0                                          256 ActiveStore
      30      224.0.0.0/4                                    0.0.0.0                                          256 ActiveStore
      30      172.17.34.255/32                               0.0.0.0                                          256 ActiveStore
      30      172.17.34.14/32                                0.0.0.0                                          256 ActiveStore
      30      172.17.34.0/24                                 0.0.0.0                                          256 ActiveStore
      Code block. Execute -ifindex
      Notice
      • If you delete the existing Default Gateway, the terminal session will be disconnected.
      • Step 2 After completing the task, if the task status changes to Completed, you can reconnect to the terminal.
  4. Connect to the server to be changed using the NAT IP and check its communication status.

    • Use the following command to verify whether any pre‑change configuration information remains and whether the change was applied correctly. * If you can successfully connect to the server targeted for IP change, the changed IP is in normal communication state.
      Color mode
      PS C:\> netstat nr | findstr Default
      PS C:\> Get-NetIPAddress | Format-Table
      PS C:\> netstat nr | findstr Default
      PS C:\> Get-NetIPAddress | Format-Table
      Code block. Communication status check
      Reference
      The NAT IP does not change.
  5. Check the VLAN information of the existing IP in the Team information.

    Color mode
    PS C:\> Get-NetLbfoTeam
    
    Name                   : bond_bond-srv
    Members                : {ens6f1, ens3f1}
    TeamNics               : {bond-srv, bond-srv.9}
    Team ingMode            : SwitchIndependent
    LoadBalancingAlgorithm : Dynamic
    Status                 : Up
    
    Name                   : bond_bond-iscsi
    Members                : {ens6f0, ens3f0}
    TeamNics               : bond-iscsi
    Team ingMode            : SwitchIndependent
    LoadBalancingAlgorithm : Dynamic
    Status                 : Up
    
    Name                   : bond_bond-backup
    Members                : {ens2f0, ens4f1}
    TeamNics               : bond-backup
    Team ingMode            : SwitchIndependent
    LoadBalancingAlgorithm : Dynamic
    Status                 : Up
    
    PS C:\> Get-NetAdapter
    
    Name                      InterfaceDescription                    ifIndex Status       MacAddress             LinkSpeed
    ----                      --------------------                    ------- ------       ----------             ---------
    bond-srv.9                Microsoft Network Adapter Multiple...#4      30 Up           40-A6-B7-27-96-D5        50 Gbps
    bond-srv                  Microsoft Network Adapter Multiple...#3      19 Up           40-A6-B7-27-96-D5        50 Gbps
    bond-iscsi                Microsoft Network Adapter Multiple...#2      18 Up           40-A6-B7-27-96-D4        50 Gbps
    bond-backup               Microsoft Network Adapter Multiplexo... 22 Up           68-05-CA-C9-EB-88        20 Gbps
    eno2                      Intel(R) Ethernet Connection X722 fo... 12 Disabled     38-68-DD-36-A0-59         1 Gbps
    ens3f0                    Intel(R) Ethernet Network Adapter XX... 11 Up           40-A6-B7-27-96-D4        25 Gbps
    ………………………………………….. Omitted
    PS C:\> Get-NetLbfoTeam
    
    Name                   : bond_bond-srv
    Members                : {ens6f1, ens3f1}
    TeamNics               : {bond-srv, bond-srv.9}
    Team ingMode            : SwitchIndependent
    LoadBalancingAlgorithm : Dynamic
    Status                 : Up
    
    Name                   : bond_bond-iscsi
    Members                : {ens6f0, ens3f0}
    TeamNics               : bond-iscsi
    Team ingMode            : SwitchIndependent
    LoadBalancingAlgorithm : Dynamic
    Status                 : Up
    
    Name                   : bond_bond-backup
    Members                : {ens2f0, ens4f1}
    TeamNics               : bond-backup
    Team ingMode            : SwitchIndependent
    LoadBalancingAlgorithm : Dynamic
    Status                 : Up
    
    PS C:\> Get-NetAdapter
    
    Name                      InterfaceDescription                    ifIndex Status       MacAddress             LinkSpeed
    ----                      --------------------                    ------- ------       ----------             ---------
    bond-srv.9                Microsoft Network Adapter Multiple...#4      30 Up           40-A6-B7-27-96-D5        50 Gbps
    bond-srv                  Microsoft Network Adapter Multiple...#3      19 Up           40-A6-B7-27-96-D5        50 Gbps
    bond-iscsi                Microsoft Network Adapter Multiple...#2      18 Up           40-A6-B7-27-96-D4        50 Gbps
    bond-backup               Microsoft Network Adapter Multiplexo... 22 Up           68-05-CA-C9-EB-88        20 Gbps
    eno2                      Intel(R) Ethernet Connection X722 fo... 12 Disabled     38-68-DD-36-A0-59         1 Gbps
    ens3f0                    Intel(R) Ethernet Network Adapter XX... 11 Up           40-A6-B7-27-96-D4        25 Gbps
    ………………………………………….. Omitted
    code block. Run Get-NetLbfoTeam

  6. Delete the Vlan information of the existing IP from the server.

    • Enter the verified ID in place of 30 in the following example.
      Color mode
      PS C:\> Remove-NetLbfoTeamNic -Team bond_bond-srv -VlanID 30 -Confirm:$false
      
      PS C:\> Get-NetAdapter
      
      Name                      InterfaceDescription                    ifIndex Status       MacAddress             LinkSpeed
      ----                      --------------------                    ------- ------       ----------             ---------
      bond-srv                  Microsoft Network Adapter Multiple...#3      19 Up           40-A6-B7-27-96-D5        50 Gbps
      bond-iscsi                Microsoft Network Adapter Multiple...#2      18 Up           40-A6-B7-27-96-D4        50 Gbps
      bond-backup               Microsoft Network Adapter Multiplexo... 22 Up           68-05-CA-C9-EB-88        20 Gbps
      eno2                      Intel(R) Ethernet Connection X722 fo... 12 Disabled     38-68-DD-36-A0-59         1 Gbps
      ens3f0                    Intel(R) Ethernet Network Adapter XX... 11 Up           40-A6-B7-27-96-D4        25 Gbps
      ………………………………………….. Omitted
      PS C:\> Remove-NetLbfoTeamNic -Team bond_bond-srv -VlanID 30 -Confirm:$false
      
      PS C:\> Get-NetAdapter
      
      Name                      InterfaceDescription                    ifIndex Status       MacAddress             LinkSpeed
      ----                      --------------------                    ------- ------       ----------             ---------
      bond-srv                  Microsoft Network Adapter Multiple...#3      19 Up           40-A6-B7-27-96-D5        50 Gbps
      bond-iscsi                Microsoft Network Adapter Multiple...#2      18 Up           40-A6-B7-27-96-D4        50 Gbps
      bond-backup               Microsoft Network Adapter Multiplexo... 22 Up           68-05-CA-C9-EB-88        20 Gbps
      eno2                      Intel(R) Ethernet Connection X722 fo... 12 Disabled     38-68-DD-36-A0-59         1 Gbps
      ens3f0                    Intel(R) Ethernet Network Adapter XX... 11 Up           40-A6-B7-27-96-D4        25 Gbps
      ………………………………………….. Omitted
      code block. Run Get-NetLbfoTeam
  7. After all tasks are completed, restart the server and then perform a final check.

    Reference
    It is recommended to perform the final check after restarting the server.

  8. If the final inspection results show no issues, select the work‑completion checkbox for Step 3 in the IP Change popup window.

Setting up RHEL Repository

The Samsung Cloud Platform Console provides the SCP RHEL Repository to support user environments where external access is restricted, such as VPC Private Subnet.
You can use the RHEL Repository to install and download the same packages as the official RHEL Repository.

To configure the RHEL Repository, refer to the RHEL Repository 설정 가이드.

안내
  • If a user created RHEL before August 2025 through the Samsung Cloud Platform Console, they must modify the RHEL Repository settings.
  • Since the SCP RHEL Repository synchronizes with each region’s local repository according to an internal schedule, it is recommended to switch to an external public mirror site to apply the latest patches quickly.
  • Samsung Cloud Platform provides the latest version repository for the given major version.
Monitoring Metrics
Install ServiceWatch Agent